1. Razlikovanje med enojni in dvosmerni tiristorji: Prvi, mer oboje poli. Če naprej in obratno merjenje kazalci naredi ne premakni (R × 1 prestava), it lahko biti A, K ali G, A pol (za enosmerne tiristorje) ali T2, T1 ali T2, G pol (za dvosmerne tiristorje). Če ena od meritev kaže desetice do sto od ohmov, it mora biti a enosmerna tiristor. In rdeča pero je povezana na K pole, črna pero je povezana na G pole, in ostal je A pole. Če oboje naprej naprej in obratno test indikacije so deset do sto ohmov, it mora biti a dvosmerno tiristor. Zavrtite gumb na R × 1 ali R × 97 10 in ponovno preskusite. Če tam je a rahlo večji upor vrednost, povežite the rdeča pero G pol % 2c povezava črna pero T1 pol % 2c in poveži preostalo T2 pol.
2. Zmogljivost razlika: Zasutev gumb do R × 1 prestava. Za 1-6A enosmerno tiristorji, povežite rdeče pero do K pole in črno pero za oboje G in A pole. Medtem ko ohranjanje črno pero v A pole stanje, prekinitev kazalec kazalec moral nakažite več deset of ohms do ene sto ohm. At to to točka, tiristor je bilo bilo sprožila in sprožilna napetost (ali tok) je nizka. Nato takoj odklop A pol in ponovno poveži to. Če kazalec kazalec bi se moral vrniti na e2�� položaj, it kaže da tiristor je v dobrom stanju.
For 1-6A bidirectional thyristors, connect the red pen to the T1 pole and the black pen to both the G and T2 poles. Disconnect the G pole while ensuring that the black pen does not detach from the T2 pole. The pointer should indicate several tens to over a hundred ohms (depending on the thyristor current and manufacturer). Then swap the two pens and repeat the above steps to measure once. If the pointer reading is slightly larger than the previous time by more than ten to tens of ohms, it indicates that the thyristor is good and the trigger voltage (or current) is small. If the G pole is disconnected while keeping the A or T2 pole connected, and the pointer immediately returns to the ∞ position, it indicates that the thyristor trigger current is too high or damaged. Further measurement can be carried out using the method shown in Figure 2. For a unidirectional thyristor, when the switch K is closed, the light should light up, and when the switch K is disconnected, the light should still not turn off. Otherwise, it indicates that the thyristor is damaged.
Za dvosmerne tiristorje, ko stikalo K je zaprto, svetloba bi morala luč gor, in ko stikalo K je odklopljeno, svetloba bi morala ne iti izstopiti. Potem obratno baterija in ponovitev zgornji koraki. Enako rezultat bi moralo biti pridobljeno za pokazati da je to je dobro. V nasprotnem primeru, it označuje da naprava je bila poškodovana.